{"id":611,"date":"2023-05-01T09:12:56","date_gmt":"2023-05-01T09:12:56","guid":{"rendered":"http:\/\/backup.industryparts.pk\/index.php\/product\/xj11-siemens-phase-failure-and-phase-sequence-voltage-relay-with-overvoltage-and-undervoltage-protective-functions-in-pakistan\/"},"modified":"2023-05-01T09:12:57","modified_gmt":"2023-05-01T09:12:57","slug":"xj11-siemens-phase-failure-and-phase-sequence-voltage-relay-with-overvoltage-and-undervoltage-protective-functions-in-pakistan","status":"publish","type":"product","link":"https:\/\/backup.industryparts.pk\/index.php\/product\/xj11-siemens-phase-failure-and-phase-sequence-voltage-relay-with-overvoltage-and-undervoltage-protective-functions-in-pakistan\/","title":{"rendered":"XJ11 Siemens Phase Failure and Phase Sequence Voltage Relay With overvoltage and undervoltage protective functions in Pakistan"},"content":{"rendered":"<h2><\/h2>\n<p><span data-mce-fragment=\"1\">Phase Sequence \u2013 This is when\u00a0<\/span><b data-mce-fragment=\"1\">the three phases are not connected in the correct sequence<\/b><span data-mce-fragment=\"1\">. If a motor is started with an incorrect phase sequence it will cause them to start in reverse which may cause damage. &#8230; Only Phase Failure Relays with Phase Asymmetry monitoring can detect this fault condition.<\/span><\/p>\n<h2>Features:\u00a0<\/h2>\n<ul>\n<li>Model XJ11, XJ3-D<\/li>\n<li>Protection function 1.over voltage protection, 2.under voltage protection ,<\/li>\n<li>3. phase failure protection, 4.phase sequence protection<\/li>\n<li>Operation power 3-phase AC380v\/220v, 50Hz\/60 Hz<\/li>\n<li>The range of voltage protection Under voltage protection: 300-380v<\/li>\n<li>Overvoltage protection: 380-460v<\/li>\n<li>Delay time range actuating time of Under-voltage protection: 2-9s<\/li>\n<li>Actuating time of Overvoltage protection:1.5-4s<\/li>\n<li>Actuating time of phase failure and phase sequence<\/li>\n<li>Protection:2s\/Max.Reset Automatically reset<\/li>\n<li>Contact capacity 5A AC380 v (resistance)<\/li>\n<li>Power consumption ?1w<\/li>\n<li>Insulation resistance ?100Mohm (20\u00b0C relative humidity 85% )<\/li>\n<li>Contact resistance ?0.03ohm<\/li>\n<li>Electrical life 1\u00d7105 times<\/li>\n<li>Ambient temperature -10C~+50C<\/li>\n<li>Ambient humidity 85% (20\u00b15<\/li>\n<li>Dielectric strength No breakdown and flashover, under the condition of lasting to<\/li>\n<li>Operate power AC (50Hz )1500V for 1 minute.<\/li>\n<li>Installation type 1. 35mm track mounting, 2. screw mounting on the backboard<\/li>\n<\/ul>\n<h3>Package Includes:<\/h3>\n<p>1 x\u00a0XJ11 Siemens Phase Failure and Phase Sequence Voltage Relay<\/p>\n<p><a title=\"https:\/\/industryparts.pk\/\" href=\"https:\/\/industryparts.pk\/\"><span style=\"color: #2b00ff;\"><strong>Industryparts. pk<\/strong><\/span><\/a> is the Best Online Shopping website for XJ11 Siemens Phase Failure and Phase Sequence Voltage Relay With overvoltage and under voltage protective functions. Here you get XJ11 Siemens Phase Failure and Phase Sequence Voltage Relay With overvoltage and under voltage protective functions at a reasonable price in Karachi, Lahore, Islamabad, Rawalpindi, Peshawar, Quetta, Multan, and all over Pakistan.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0387\/8082\/9836\/files\/XJ11SiemensPhaseFailureandPhaseSequenceVoltageRelayWithovervoltageandundervoltageprotectivefunctionsinPakistan_480x480.jpg?v=1642760665\" alt=\"\"><img decoding=\"async\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0387\/8082\/9836\/files\/XJ11SiemensPhaseFailureandPhaseSequenceVoltageRelayWithovervoltageandundervoltageprotectivefunctionsinPakistan_4d13947b-80e1-4470-b0b0-2ef53571570c_480x480.jpg?v=1642760681\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0387\/8082\/9836\/files\/XJ11SiemensPhaseFailureandPhaseSequenceVoltageRelayWithovervoltageandundervoltageprotectivefunctionsinPakistan_4d13947b-80e1-4470-b0b0-2ef53571570c_480x480.jpg?v=1642760681\" data-mce-fragment=\"1\"><\/p>\n<ul><\/ul>\n<ul><\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Phase Sequence \u2013 This is when\u00a0the three phases are not connected in the correct sequence. If a motor is started with an incorrect phase sequence it will cause them to start in reverse which may cause damage. &#8230; Only Phase Failure Relays with Phase Asymmetry monitoring can detect this fault condition. Features:\u00a0 Model XJ11, XJ3-D [&hellip;]<\/p>\n","protected":false},"featured_media":4585,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[36465,36466,36384,36473,36477,36408],"product_tag":[1858,1926,3727,3728,1860,3729,3730,1863,1929,1932,3731,3732,1865,3733,3734,3735,3736,3737,1872,3738,3739,3740,371,126,3741,3742,3743,3744,3745,3746,3747,3748,3749,3750,3751,3752,3753,3754,3755,3756],"_links":{"self":[{"href":"https:\/\/backup.industryparts.pk\/index.php\/wp-json\/wp\/v3\/product\/611"}],"collection":[{"href":"https:\/\/backup.industryparts.pk\/index.php\/wp-json\/wp\/v3\/product"}],"about":[{"href":"https:\/\/backup.industryparts.pk\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/backup.industryparts.pk\/index.php\/wp-json\/wp\/v2\/comments?post=611"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/backup.industryparts.pk\/index.php\/wp-json\/wp\/v2\/media\/4585"}],"wp:attachment":[{"href":"https:\/\/backup.industryparts.pk\/index.php\/wp-json\/wp\/v2\/media?parent=611"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/backup.industryparts.pk\/index.php\/wp-json\/wp\/v2\/product_cat?post=611"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/backup.industryparts.pk\/index.php\/wp-json\/wp\/v2\/product_tag?post=611"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}